Rosemount 214CTKAKT1DUM0360DFAR2C2UAB1E200G1G N1XAXW, Temperature Sensor, Sensor Type: Thermocouple Type K, -40 to 1200?C (-40 to 2192?F), Sensor Sheath Material: Alloy 600 Sensor Accuracy: Class 1 per IEC 60584, Sensor Wire Configuration: Dual, Ungrounded, Isolated, Dimension Units: Metric Units (mm)Sensor Insertion Length (L): xxxx mm, 0 to 2000 mm in 5 mm increments. Sensor Mounting Style (Fittings and Adapters): DIN Mounting Plate with Flying Leads Connection Head: Rosemount Aluminum with Meter Cover, Conduit Entry: M20 x 1.5 Instrument Connection: 1/2 inch NPT, Cable Glands: Ex d, Standard Cable Diameter, Extension Type: Union Style, 1/2 inch NPT, 1/2 inch NPT, Extension Length (E): 200 mm, Ground Screw: External Ground Screw, Transmitter Assembled To Sensor: Process Ready Assembly of Transmitter and Sensor, Thermowell Assembled To Sensor: Process Ready Assembly of Sensor and Thermowell, C/W Rosemount 114CM0300PAM2SG060AQ8R21XW, Thermowell Dimensional Units: Metric Units Immersion Length: XXXX mm, 5 mm increments from 25 to 2500 mm Mounting Style: Flange, Partial Penetration Weld Process Connections: 1 1/2" Class 400/600 Stem Style: Tapered Stem, Thermowell Material: 316Ti SST Head Length: XXX mm, 5 mm increments from 40 mm to 225 mm Instrument Connection: 1/2"-14 ANPT, Material Certification:Thermowell Calculation:Sensor/ Thermowell Assemble to Options: Process ready assembly of a sensor and thermowell AND Rosemount 644HANAXAM5C4Q4 Temperature Transmitter, Transmitter Type and Measurement Configuration: DIN A Head Mount - Single Sensor Input, Transmitter Output: 4-20 mA with digital signal based on HART protocol, Product Certifications: No Hazardous Location Approval, Display and Interface Options: LCD Display, 5-Point Calibration: 5-Point Calibration, Calibration Certificate: Calibration Certificate (3-Point Calibration, Assemble To Options: Process Ready assembly of a transmitter and sensor, 0 to 500 DEG C K2

Non-stocks
764671
Requires Quote

Rosemount 214CTKAKT1DUM0360DFAR2C2UAB1E200G1G N1XAXW, Temperature Sensor, Sensor Type: Thermocouple Type K, -40 to 1200?C (-40 to 2192?F), Sensor Sheath Material: Alloy 600 Sensor Accuracy: Class 1 per IEC 60584, Sensor Wire Configuration: Dual, Ungrounded, Isolated, Dimension Units: Metric Units (mm)Sensor Insertion Length (L): xxxx mm, 0 to 2000 mm in 5 mm increments. Sensor Mounting Style (Fittings and Adapters): DIN Mounting Plate with Flying Leads Connection Head: Rosemount Aluminum with Meter Cover, Conduit Entry: M20 x 1.5 Instrument Connection: 1/2 inch NPT, Cable Glands: Ex d, Standard Cable Diameter, Extension Type: Union Style, 1/2 inch NPT, 1/2 inch NPT, Extension Length (E): 200 mm, Ground Screw: External Ground Screw, Transmitter Assembled To Sensor: Process Ready Assembly of Transmitter and Sensor, Thermowell Assembled To Sensor: Process Ready Assembly of Sensor and Thermowell, C/W Rosemount 114CM0300PAM2SG060AQ8R21XW, Thermowell Dimensional Units: Metric Units Immersion Length: XXXX mm, 5 mm increments from 25 to 2500 mm Mounting Style: Flange, Partial Penetration Weld Process Connections: 1 1/2" Class 400/600 Stem Style: Tapered Stem, Thermowell Material: 316Ti SST Head Length: XXX mm, 5 mm increments from 40 mm to 225 mm Instrument Connection: 1/2"-14 ANPT, Material Certification:Thermowell Calculation:Sensor/ Thermowell Assemble to Options: Process ready assembly of a sensor and thermowell AND Rosemount 644HANAXAM5C4Q4 Temperature Transmitter, Transmitter Type and Measurement Configuration: DIN A Head Mount - Single Sensor Input, Transmitter Output: 4-20 mA with digital signal based on HART protocol, Product Certifications: No Hazardous Location Approval, Display and Interface Options: LCD Display, 5-Point Calibration: 5-Point Calibration, Calibration Certificate: Calibration Certificate (3-Point Calibration, Assemble To Options: Process Ready assembly of a transmitter and sensor, 0 to 500 DEG C K2

QTY